IEC 61514:2000 pdf download-Industrial-process control systems – Methods of evaluating the performance of valve positioners with pneumatic outputs

01-18-2022 comment

IEC 61514:2000 pdf download-Industrial-process control systems – Methods of evaluating the performance of valve positioners with pneumatic outputs.
The test values shall be corrected back to the standard reference atmosphere conditions listed above. The standard reference atmosphere is equivalent to the normal reference operating conditions commonly identified by the manufacturer. It is recognized that there may not be a factor to correct for humidity. When measurements within the recommended range of ambient conditions are unsatisfactory, and the correction factors to adjust parameters to the standard atmosphere are unknown, repeat measurements (referee measurements) may be conducted under the conditions listed in table 1 , a or b, or other reference operating conditions identified by the manufacturer. NOTE Special equipment may be required to maintain the basic test conditions within the limits specified. 4.1 .1 Recommended limits of ambient conditions for test measurements Electromagnetic field: value to be stated, if relevant. Maximum rate of change of ambient temperature permissible during any test: 1 °C in 1 0 min, but not more than 3 °C/h. 4.2 Supply conditions 4.2.1 Reference values Electrical supply: the values specified by the manufacturer. Pneumatic supply: the values specified by the manufacturer, or a supply pressure of 4,0 bar (400 kPa).
5 General testing procedures 5.1 Test equipment When the accuracy rating of the reference measuring means is one-tenth or less than that of the device under test, the accuracy rating of the reference measuring means may be ignored in calculations, but shall be reported. When the accuracy rating of the reference measuring means is one-third or less, but greater than one-tenth of that of the device under test, the accuracy rating of the reference measuring means shall be stated in the report. 5.2 Test methods Specific test methods and test configurations are described separately in clause 6. 5.3 Testing precautions Unless affecting the influence condition being tested, the following conditions shall apply. An adequate time, as specified by the manufacturer, shall be allowed after switching on the power supply in order to allow stabilization of the positioner and/or associated test equipment. In the absence of a manufacturer specification, a period of at least 1 5 min shall be allowed (at least 30 min for electrical supplies).

Download Link Download
PS: If you don't mind, please turn off your ad blocker.
AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment IEC standards free download

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment. 5.2.4 Instructions for use Additionally to the requirements of the general standard...
   Read More
AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters IEC standards free download

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters. 3.3 Terms and definitions concerning a.c. semiconductor motor controllers and starters 3.3.1 semiconductor switching device switching device designed...
   Read More
AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function IEC standards free download

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function. 4.3 Additional requirements for trip wire switches Information provided by the manufacturer shall include:...
   Read More
AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR) IEC standards free download

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR)

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR). 6 Product information Characteristic product data shall be stated by the manufacturer together...
   Read More

LEAVE A REPLY

Anonymous netizen Fill in information