BS ISO/IEC 7811-9:2015 pdf download-Identification cards — Recording technique Part 9: Tactile identifier mark

01-19-2022 comment

BS ISO/IEC 7811-9:2015 pdf download-Identification cards — Recording technique Part 9: Tactile identifier mark.
1 Scope This part of ISO/IEC 7811 specifies the physical characteristics of a tactile identifier mark used by visually impaired card holders to distinguish their cards. It defines the area on the card for the TIM and the layout of Braille style embossed dots arranged in patterns to enable easy tactile recognition. 2 Conformance A TIM is in conformance with this part of ISO/IEC 7811 if it meets all mandatory requirements and optional requirements as specified. 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO/IEC 7810 and the following apply. 3.1 TIM tactile identifier mark 3.2 embossed raised in relief from the front surface of the card by adding or reacting card material or by deforming the card material from the opposite side 4 TIM physical characteristics 4.1 Location of TIM The TIM should be located on the front surface of the card in the area shown in Figure 1. The TIM shall not be located outside the name and address area defined by ISO/IEC 7811-1. Regardless of TIM location, all other raised areas shall be at least 1 mm from the edge of any TIM. When the technology used to form the raised areas causes a physical deformation of the card such as mechanical embossing, then special care shall be taken that such deformation of the card does not adversely affect the required characteristics of the contained components such as IC, antenna, connecting wires, etc. A minimum distance of 3 mm between the contained components and any deformed part of the card is recommended unless it is known that the components are not affected by the deformation of the card.
The recommended TIM location is shown in Figure 1 as “Default area”. If the “Alternate area” for TIM is used, there shall be no other raised area to the right and below the TIM dots (between TIM dots and nearest edges of card). NOTE The alternate area is raised up to avoid overlapping on the antenna of a contactless IC card but is still low enough to be in the name and address area as required and to be at least 1 mm away from the primary account line (both specified in ISO/IEC 7811-1).

Download Link Download
PS: If you don't mind, please turn off your ad blocker.
AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment IEC standards free download

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment. 5.2.4 Instructions for use Additionally to the requirements of the general standard...
   Read More
AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters IEC standards free download

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters. 3.3 Terms and definitions concerning a.c. semiconductor motor controllers and starters 3.3.1 semiconductor switching device switching device designed...
   Read More
AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function IEC standards free download

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function. 4.3 Additional requirements for trip wire switches Information provided by the manufacturer shall include:...
   Read More
AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR) IEC standards free download

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR)

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR). 6 Product information Characteristic product data shall be stated by the manufacturer together...
   Read More

LEAVE A REPLY

Anonymous netizen Fill in information