IEC 62372:2021 pdf download-Nuclear instrumentation – Housed scintillators – Test methods of light output and intrinsic resolution

01-18-2022 comment

IEC 62372:2021 pdf download-Nuclear instrumentation – Housed scintillators – Test methods of light output and intrinsic resolution.
For each value of energy, the position of a maximum of a peak of full absorption is defined. The values of the nonlinearity and the initial point of assembly conversion response shall be defined using a housed scintillator based on thallium-activated sodium iodide single crystal during irradiation by gamma-radiation. Pulse height spectra are measured using monoenergetic gamma radiation with at least five energy values in the range from 300 keV to 1 500 keV. For each energy value the total absorption peak maximum position should be defined. The light output of a housed scintillator may be used to determine the nonlinearity and the initial point of assembly conversion response in cases where it is necessary to measure the parameters of housed scintillators with low light output. For that, light flux from housed scintillator is attenuated by a neutral light filter. The pulse heights obtained after attenuation should correspond to the working range of pulse heights of the tested scintillator. Neutral light absorbers are added after the PMT power supply is turned off and the light protection chamber is opened. After setting the light absorber, the chamber is closed, the PMT power supply is turned on and measurements are taken after not less than half an hour’s irradiation. The values of nonlinearity and V o are measured at the same gain factor which is used for measuring the parameters of tested housed scintillator. The nonlinearity and V o should be measured once per month or more frequently, after PMT replacement or assembly repair.
4.2.1 .2 Measurements The test conditions and the order of measurements are in accordance with 4.1 . The value of pulse heights (V) corresponding to total absorption peak maximum is determined. The measurements are repeated three times and the average value V is calculated. All above-mentioned procedures are repeated for each value of energy (E i ). The pulse height spectra may be accumulated simultaneously from all the gamma-emitting sources during irradiation of the housed scintillator.

Download Link Download
PS: If you don't mind, please turn off your ad blocker.
AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment IEC standards free download

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment. 5.2.4 Instructions for use Additionally to the requirements of the general standard...
   Read More
AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters IEC standards free download

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters. 3.3 Terms and definitions concerning a.c. semiconductor motor controllers and starters 3.3.1 semiconductor switching device switching device designed...
   Read More
AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function IEC standards free download

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function. 4.3 Additional requirements for trip wire switches Information provided by the manufacturer shall include:...
   Read More
AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR) IEC standards free download

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR)

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR). 6 Product information Characteristic product data shall be stated by the manufacturer together...
   Read More

LEAVE A REPLY

Anonymous netizen Fill in information