BS ISO/IEC 17991:2015 pdf download-Information technology — Office equipment — Method for Measuring Scanning Productivity of Digital Multifunctional Devices

01-19-2022 comment

BS ISO/IEC 17991:2015 pdf download-Information technology — Office equipment — Method for Measuring Scanning Productivity of Digital Multifunctional Devices.
4.4 Maintenance Scanning device maintenance shall be performed throughout testing per the manufacturer’s recommendations. 4.5 Preparation of Test Targets (Test Charts) The scanning test file is outlined in Annex C. This test file is from ISO/IEC 24735 “Method of measuring digital copying productivity”. The test file consists of 4 single sided pages. When using the test file for the scanning productivity test, the test targets shall be created by printing the most recent electronic test file on the device to be tested if it has print capability. If the test device to be tested does not have a printer function or if the device is a colour capable scanner but does not have a printing function of colour test targets (for the colour scanning test), then record the name of printer which is used to print out the actual test targets. The most recent official electronic file (ISO_IEC_24735_2009_Test_Pages.pdf) can be located at http://standards.iso. org/ittf/PubliclyAvailableStandards/SC28_Test_Pages/ . As for preparation method for double-sided targets, refer to Annex C. The quality of test targets may affect the productivity measurement. Test targets should be created according to the following: a) The test targets shall be printed by the equipment to be tested itself in its default-printing mode. (If the test device to be tested does not have a printer function or if the device is a colour capable scanner but does not have a printing function of colour test targets (for the colour scanning test), then record the name of printer which is used to print out the actual test targets.) b) The paper used for creating the test targets shall have a brightness of at least 80 % to eliminate the influence of background. c) The paper used for creating the test targets shall be 64 g/m 2 or above and sufficiently opaque to prevent scanning of images on the backside. d) The paper used for creating the test targets shall be free of wrinkles or other surface defects.

Download Link Download
PS: If you don't mind, please turn off your ad blocker.
AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment IEC standards free download

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment. 5.2.4 Instructions for use Additionally to the requirements of the general standard...
   Read More
AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters IEC standards free download

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters. 3.3 Terms and definitions concerning a.c. semiconductor motor controllers and starters 3.3.1 semiconductor switching device switching device designed...
   Read More
AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function IEC standards free download

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function. 4.3 Additional requirements for trip wire switches Information provided by the manufacturer shall include:...
   Read More
AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR) IEC standards free download

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR)

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR). 6 Product information Characteristic product data shall be stated by the manufacturer together...
   Read More

LEAVE A REPLY

Anonymous netizen Fill in information