BS ISO/IEC 17821:2015 pdf download-Information technology — Specification of low power wireless mesh network over channel-hopped TDMA links

01-19-2022 comment

BS ISO/IEC 17821:2015 pdf download-Information technology — Specification of low power wireless mesh network over channel-hopped TDMA links.
6.1 Starting the LPWMN 6.1.1 Starting a link network The gateway router which is not currently joined to a link network shall attempt to establish a new LPWMN. When the next higher layer of the device issues the DLN-START-NETWORK.request primitive, the procedure to establish a new LPWMN is initiated. If the device is not the gateway router or is joined to a link network, the DLNE shall terminate the procedure and notify the next higher layer of the illegal request by issuing the DLN-START-NETWORK.confirm primitive with the Status parameter set to INVALID_ REQUEST. The DLNE shall reset the MAC sublayer by issuing the MLME-RESET.request primitive with the SetDefaultPIB parameter set to TRUE. The DLNE shall collect the data on the wireless environments and neighbour networks by requesting that the MAC sublayer performs an energy detection scan and an active scan in succession. The DLNE issues the MLME-SCAN.request primitive with the ScanType parameter set to ED and the ScanChannels parameter set to the ScanChannels parameter of the DLN- START-NETWORK.request primitive. On receipt of the results via MLME-SCAN.confirm primitive, the DLNE shall select the channels, whose energy levels are beyond an acceptable level, at most the number of channels specified in the HoppingSequenceLength parameter of the DLN-START-NETWORK. request primitive. The DLNE issues the MLME-SCAN.request primitive with the ScanType parameter set to ACTIVE and the ScanChannels parameter set to the ScanChannels parameter of the DLN-START- NETWORK.request primitive. On receipt of the results via MLME-SCAN.confirm primitive, the DLNE shall review the PANDescriptorList parameter. The DLNE collects the information on the neighbour IEEE 802.15.4-2011 PANs: the PAN identifier, channel number and channel page, superframe specification, and the time at which the beacon frame was received.

Download Link Download
PS: If you don't mind, please turn off your ad blocker.
AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment IEC standards free download

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment. 5.2.4 Instructions for use Additionally to the requirements of the general standard...
   Read More
AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters IEC standards free download

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters. 3.3 Terms and definitions concerning a.c. semiconductor motor controllers and starters 3.3.1 semiconductor switching device switching device designed...
   Read More
AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function IEC standards free download

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function. 4.3 Additional requirements for trip wire switches Information provided by the manufacturer shall include:...
   Read More
AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR) IEC standards free download

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR)

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR). 6 Product information Characteristic product data shall be stated by the manufacturer together...