AS/NZS IEC 60947.7.3:2015 pdf download-Low-voltage switchgear and controlgear Part 7.3: Ancillary equipment—Safety requirements for fuse terminal block

01-19-2022 comment

AS/NZS IEC 60947.7.3:2015 pdf download-Low-voltage switchgear and controlgear Part 7.3: Ancillary equipment—Safety requirements for fuse terminal block.
5 Product information 5.1 Marking A fuse terminal block shall be marked in a durable and legible manner with the following: a) the name of the manufacturer or a trade mark, by which the manufacturer can be readily identified; b) a type reference permitting its identification in order to obtain relevant information from the manufacturer or his catalogue; c) energy flow direction, if required to ensure protection against electric shock, according to 7.1 .8, e.g. line-load marking or ?. 5.2 Additional information The following information shall be stated by the manufacturer, if applicable, e.g in the manufacturer’s data sheet or catalogue or on the packing unit: a) IEC 60947-7-3, if the manufacturer claims compliance with this standard; b) the rated cross-section; c) the rated connecting capacity, if different from Table 2 of IEC 60947-7-1 , including the number of conductors simultaneously connectable; d) the rated insulation voltage (U i ) of the terminal block base and the fuse-carrier, if applicable; e) the working voltage or working voltage range, primarily determined by the fuse-link or by additional components, e.g. illuminated indicators; f) rated impulse withstand voltage (U imp ); NOTE This value may be marked on the fuse terminal block only if the rated insulation voltage (U i ) or the working voltage is also marked on the fuse terminal block, e.g. 250 V/4 kV. g) rated value of the power dissipation for overload and short-circuit protection (P V ) and rated current of the fuse-link as declared by the manufacturer − in case of separate arrangement, − in case of compound arrangement; h) rated value of the power dissipation for exclusive short-circuit protection (P VK ) and rated current of the fuse-link as declared by the manufacturer − in case of separate arrangement, − in case of compound arrangement; i) operating conditions, if different from Clause 6; j) size of the fuse-link.

Download Link Download
PS: If you don't mind, please turn off your ad blocker.
AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment IEC standards free download

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment

AS/NZS IEC 60601.1.3:2015 pdf download-Medical electrical equipment Part 1.3: General requirements for basic safety and essential performance— Collateral Standard: Radiation protection in diagnostic X-ray equipment. 5.2.4 Instructions for use Additionally to the requirements of the general standard...
   Read More
AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters IEC standards free download

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters

AS/NZS IEC 60947.4.2:2015 pdf download-Low-voltage switchgear and controlgear Part 4.2: Contactors and motor- starters—AC semiconductor motor controllers and starters. 3.3 Terms and definitions concerning a.c. semiconductor motor controllers and starters 3.3.1 semiconductor switching device switching device designed...
   Read More
AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function IEC standards free download

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function

AS/NZS IEC 60947.5.5:2015 pdf download-Low-voltage switchgear and controlgear Part 5.5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function. 4.3 Additional requirements for trip wire switches Information provided by the manufacturer shall include:...
   Read More
AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR) IEC standards free download

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR)

AS/NZS IEC 60947.5.6:2015 pdf download-Low-voltage switchgear and controlgear Part 5.6: Control circuit devices and switching elements—DC interface for proximity sensors and switching amplifiers (NAMUR). 6 Product information Characteristic product data shall be stated by the manufacturer together...
   Read More

LEAVE A REPLY

Anonymous netizen Fill in information